@ -26,6 +26,7 @@ IOP( "nrs", BSIM3_NRS, IF_REAL , "Number of squares in source"), |
|
|
|
IOP( "off", BSIM3_OFF, IF_FLAG , "Device is initially off"), |
|
|
|
IOP( "nqsmod", BSIM3_NQSMOD, IF_INTEGER, "Non-quasi-static model selector"), |
|
|
|
IOP( "acnqsmod", BSIM3_ACNQSMOD, IF_INTEGER, "AC NQS model selector"), |
|
|
|
IOP( "geo", BSIM3_GEO, IF_INTEGER, "ACM model drain/source connection"), |
|
|
|
IOP( "delvto", BSIM3_DELVTO, IF_REAL, "Zero bias threshold voltage variation"), |
|
|
|
IOP( "mulu0", BSIM3_MULU0, IF_REAL, "Low field mobility multiplier"), |
|
|
|
IP( "ic", BSIM3_IC, IF_REALVEC , "Vector of DS,GS,BS initial voltages"), |
|
|
|
@ -66,6 +67,8 @@ IOP( "capmod", BSIM3_MOD_CAPMOD, IF_INTEGER, "Capacitance model selector"), |
|
|
|
IOP( "mobmod", BSIM3_MOD_MOBMOD, IF_INTEGER, "Mobility model selector"), |
|
|
|
IOP( "noimod", BSIM3_MOD_NOIMOD, IF_INTEGER, "Noise model selector"), |
|
|
|
IOP( "acnqsmod", BSIM3_MOD_ACNQSMOD, IF_INTEGER, "AC NQS model selector"), |
|
|
|
IOP( "acm", BSIM3_MOD_ACMMOD, IF_INTEGER, "Area calculation method selector"), |
|
|
|
IOP( "calcacm", BSIM3_MOD_CALCACM, IF_INTEGER, "Area calculation method ACM=12"), |
|
|
|
IOP( "paramchk", BSIM3_MOD_PARAMCHK, IF_INTEGER, "Model parameter checking selector"), |
|
|
|
IOP( "binunit", BSIM3_MOD_BINUNIT, IF_INTEGER, "Bin unit selector"), |
|
|
|
IOP( "version", BSIM3_MOD_VERSION, IF_STRING, " parameter for model version"), |
|
|
|
@ -210,6 +213,15 @@ IOP( "cle", BSIM3_MOD_CLE, IF_REAL, "Vdsat parameter for C-V model"), |
|
|
|
IOP( "dwc", BSIM3_MOD_DWC, IF_REAL, "Delta W for C-V model"), |
|
|
|
IOP( "dlc", BSIM3_MOD_DLC, IF_REAL, "Delta L for C-V model"), |
|
|
|
|
|
|
|
IOP( "hdif", BSIM3_MOD_HDIF, IF_REAL, "ACM Parameter: Distance Gate - contact"), |
|
|
|
IOP( "ldif", BSIM3_MOD_LDIF, IF_REAL, "ACM Parameter: Length of LDD Gate-Source/Drain"), |
|
|
|
IOP( "ld", BSIM3_MOD_LD, IF_REAL, "ACM Parameter: Length of LDD under Gate"), |
|
|
|
IOP( "rd", BSIM3_MOD_RD, IF_REAL, "ACM Parameter: Resistance of LDD drain side"), |
|
|
|
IOP( "rs", BSIM3_MOD_RS, IF_REAL, "ACM Parameter: Resistance of LDD source side"), |
|
|
|
IOP( "rdc", BSIM3_MOD_RDC, IF_REAL, "ACM Parameter: Resistance contact drain side"), |
|
|
|
IOP( "rsc", BSIM3_MOD_RSC, IF_REAL, "ACM Parameter: Resistance contact source side"), |
|
|
|
IOP( "wmlt", BSIM3_MOD_WMLT, IF_REAL, "ACM Parameter: Width shrink factor"), |
|
|
|
|
|
|
|
IOP( "alpha0", BSIM3_MOD_ALPHA0, IF_REAL, "substrate current model parameter"), |
|
|
|
IOP( "alpha1", BSIM3_MOD_ALPHA1, IF_REAL, "substrate current model parameter"), |
|
|
|
IOP( "beta0", BSIM3_MOD_BETA0, IF_REAL, "substrate current model parameter"), |
|
|
|
|