question: |
At 200 kHz, a spark has total capacitance C_total = 12 pF.
(a) What is R_opt_power?
(b) If V_top = 400 kV, estimate the maximum deliverable power (assume R is at
optimal value and φ_Z ≈ -70°)
hints:
- "R_opt_power = 1/(ω × C_total)"
- "Power = 0.5 × |V|² × Re{Y}"
- "Or use: P = 0.5 × |V|²/|Z| × cos(φ_Z)"
- "At R_opt_power, typical phase is around -65° to -75°"
solution:
steps:
- "Part (a): Calculate R_opt_power"
- "ω = 2π × 200×10³ = 1.257×10⁶ rad/s"
- "R_opt_power = 1/(ω × C_total)"
- "= 1/(1.257×10⁶ × 12×10⁻¹²)"
- "= 1/(15.08×10⁻⁶)"
- "= 66.3 kΩ"
- "Part (b): Estimate maximum power"
- "At R_opt_power with given capacitances, φ_Z ≈ -70° (typical)"
- "Approximate |Z| ≈ R_opt_power / cos(-70°) = 66.3/0.342 ≈ 194 kΩ"
- "Current: I = V/|Z| = 400×10³/194×10³ = 2.06 A peak"
- "Power: P = 0.5 × V × I × cos(φ_Z)"
- "= 0.5 × 400×10³ × 2.06 × cos(-70°)"
- "= 0.5 × 400×10³ × 2.06 × 0.342"
- "= 141 kW"
- "Alternative: P ≈ 0.5 × I² × R = 0.5 × 2.06² × 66.3×10³ ≈ 141 kW"
answer_a: "66.3"
answer_b: "141"
unit_a: "kΩ"
unit_b: "kW"
tolerance: 5.0
explanation: |
R_opt_power is determined solely by frequency and total capacitance. At this
resistance, power transfer is maximized. The estimated power (141 kW) is
substantial, but achievable for medium-to-large DRSSTCs. This calculation shows
why R_opt_power is critical for performance - operating far from this value
significantly reduces delivered power. The estimate uses typical phase angle
for operation at R_opt_power; exact value would require full admittance calculation.
related_concepts: ["R_opt_power", "maximum-power-transfer", "power-estimation"]